2, 4 & 19 Channel Instantaneous Z Score EEG Biofeedback. In 2004 Applied Neuroscience, Inc. invented Z score EEG biofeedback. The 1st real-time or "live" Z score controlling biofeedback was distributed as a dynamic link library (DLL) to companies in 2004. Agreements were formed with companies that already had existing scalp surface EEG Biofeedback products using raw EEG data. These companies wanted to use their software environment to add Z scores based on the raw values computed in about 1 microsecond or in real-time for 2, 4 and 19 channels.
-
Update Subscription expired? Purchase an Update Subscription so you can download and install the latest releases of NeuroGuide software for 1 year. Not sure if your Update Subscription has expired.. then Open NG click on Help and select License Information. The Update Subscription Expiration date will be above the Customer ID or at the bottom of License Information window, depending on your current version on NeuroGuide.
-
Charge for 1 Replacement or 1 Transfer Key B for any of the Z Score DLLs after the first 2 Transfer B Keys have been issued, with a maximum of one license transfer per year per licensee. Prior to ANI issuing a Transfer or Replacement Key B the Licensee must personally email [email protected] and Certify that the computer has crashed or that the user has removed the DLL from the previous computer and the user must promise not to run the DLL on more than two computers.
-
swLORETA Z Score Neurofeedback: Z Score swLORETA biofeedback of Brodmann areas in the brain, “Hubs”, “Modules” and “Default Mode Network” and 3-dimensional locations registered to a reference MRI. Includes ‘Live’ swLORETA Coherence & Phase Differences from 88 Brodmann Areas, plus the Thalamus, Vermis, Red Nucleus and the Cerebellum Regions of Interests.
-
swLORETA Z Score Cross-Frequency Neurofeedback includes Linked Ears real-time Z scores. 'Live' or Real-time, coherence & phase amplitude Z scores. Includes a Symptom Check List and swLORETA EEG Z Scores to help structure a biofeedback protocol design. swLORETA Z scores measured during a QEEG analysis are also used to further aid in the development of a neurofeedback protocol.
-
swBrainSurfer-2 for a 2nd License NeuroGuide. Our Brain Computer Interface with 12,270 voxels, 3-D NeuroImaging of Functional Brain Networks and swLORETA of Brodmann Areas in Real-time and Live Z scores of nodes and connections between nodes as measured by the connectivity of swLORETA Coherence, swLORETA Lagged Coherence, Phase Differences and swLORETA Phase Slope Index (Information Flow). Must have swBrainSurfer on previously purchased full priced NeuroGuide.
-
swBrainSurfer is a Brain Computer Interface with a real-MRI with 12,270 voxels, 3-D NeuroImaging of Functional Brain Networks and swLORETA of Brodmann Areas in Real-time and Live Z scores of nodes and connections between nodes as measured by the connectivity of swLORETA Coherence, swLORETA Lagged Coherence, Phase Differences and swLORETA Phase Slope Index (Information Flow).
-
Surface Cross-Frequency Power is an EEG measure of the correlation of power between frequencies and scalp locations, for example delta and beta or theta and alpha-2 or theta and high beta (Gamma), etc. A given brain region communicates with other brain region over a range of frequencies. Currently available for Raw Values Only.
-
The amplitude of higher EEG frequencies (e.g., beta) are related to the phase of lower EEG frequencies (e.g., theta). Therefore, this is a surface EEG measure of the correlation between the phase and amplitude of the EEG across frequencies and scalp locations, for example delta and beta or theta and alpha-2 or theta and high beta (Gamma), etc. This is a unique and important metric that in part reflects the coupling between the upper cortical layers (I-III that generate beta) and the lower cortical layers (V-VI) that generate delta and theta. This add-on quantifies the coupling and provides a normative database comparison (Z scores) to help link symptoms to dysregulation in the brain.
-
Surface Cross-Frequency Coherence is an EEG measure of the Coherence (amplitude independent coupling) between frequencies and scalp locations, for example delta & beta or theta & alpha-2 or theta & high beta (Gamma), etc. A given brain region communicates with other brain regions over a range of frequencies. This add-on quantifies the coupling and provides a normative database comparison (Z scores) to help link symptoms to dysregulation in the brain.
-
Surface 1 to 19 Channel Z Score Neurofeedback includes Average Reference, Linked Ears and Laplacian real-time Z scores. 'Live' or Real-time, coherence, phase difference, power, amplitude asymmetry, phase shift and phase lock duration Z scores. Includes a Symptom Check List and Surface EEG Z Scores to help structure a biofeedback protocol design. LORETA Z scores measured during a QEEG analysis are also used to further aid in the development of a neurofeedback protocol.
-
Surface 1 to 19 Channel Z Score Cross-Frequency Neurofeedback includes Linked Ears real-time Z scores. 'Live' or Real-time, coherence & phase amplitude Z scores. Includes a Symptom Check List and Surface EEG Z Scores to help structure a biofeedback protocol design. sLORETA Z scores measured during a QEEG analysis are also used to further aid in the development of a neurofeedback protocol.
-
NeuroGuide Acquisition (NGA + swNF) is a Stand alone EEG acquisition - useful for Satellite Clinics. Includes collection of EEG and real-time swLORETA EEG Biofeedback of Z scores of Power, Coherence, Phase Difference, Phase Lock, Phase Shift with Integrated Symptom Checklists that includes 88 Brodmann Areas, plus the Thalamus, Vermis, Red Nucleus and the Cerebellum Regions of Interests. No qEEG or editing capability. Does not require the purchase of NeuroGuide. Only one license per purchase is permitted, i.e., a 2nd license requires a 2nd purchase.
-
NeuroGuide Acquisition (NGA + NF3) is a Stand alone EEG acquisition - useful for Satellite Clinics. Includes collection of EEG and real-time Surface EEG Biofeedback of Z scores of the Laplacian, Average Reference, Linked Ears Phase Difference with Integrated Symptom Checklists. No qEEG or editing capability. Does not require the purchase of NeuroGuide. Only one license per purchase is permitted, i.e., a 2nd license requires a 2nd purchase.
-
NeuroGuide Acquisition (NGA + NF2) is a Stand alone EEG acquisition - useful for Satellite Clinics. Includes collection of EEG and real-time 3-D LORETA EEG Biofeedback of Z scores of Power, Coherence, Phase Difference, Phase Lock, Phase Shift with Integrated Symptom Check Lists. No qEEG or editing capability. Does not require the purchase of NeuroGuide. Only one license per purchase is permitted, i.e., a 2nd license requires a 2nd purchase.
-
NeuroGuide Acquisition (NGA + NF1) is a Stand alone EEG acquisition - useful for Satellite Clinics. Includes collection of EEG and real-time Surface EEG Biofeedback of Z scores of the Laplacian, Average Reference, Linked Ears, Coherence, Phase Difference, Phase Lock, Phase Shift, Relative Power, Absolute Power with Integrated Symptom Check Lists. No qEEG or editing capability. Does not require the purchase of NeuroGuide. Only one license per purchase is permitted, i.e., a 2nd license requires a 2nd purchase.
-
NeuroGuide Acquisition (NGA + Surf) is a Stand alone EEG acquisition - useful for Satellite Clinics. Includes collection of EEG and a 3-D image of the Brain with real-time Z scores of Power, Coherence, Phase Difference, Phase Lock, Phase Shift with Integrated Symptom Check Lists. No qEEG or editing capability. Does not require the purchase of NeuroGuide. Only one license per purchase is permitted, i.e., a 2nd license requires a 2nd purchase.
-
An EEG statistics program for test-retest and group analyses. It only takes a few mouse clicks to publish your results! Individual comparison options are independent t-tests, paired t-tests, and repeated measures analysis of variance (ANOVA) as well as absolute and percent differences for Surface EEG as well as LORETA.
Descriptive Group statistics include Means and Standard Deviations and independent t-tests between Groups (does not assume equal variance or sample sizes). Some group comparative statistics require the use of NeuroBatch™ to produce a NeuroGuide™ Group Analysis File.
-
Add NeuroNavigator's swLORETA Phase Shift & Phase Lock to your 2nd NeuroGuide License, Real-Time NeuroNavigator† and the NeuroNavigator Time Domain Capture to view the Raw Scores and/or Z Scores of Phase Shift and Phase Lock by purchasing the swLORETA Phase Reset Normative Database (NNPR-2). Must first purchase NeuroNavigator (NN-2) and the swLORETA Current Source Density Normative Database (NNZ-2) add-ons for you 2nd NeuroGuide License.
-
Add swLORETA Phase Shift & Phase Lock to your NeuroGuide NeuroNavigator, Real-Time NeuroNavigator† and the NeuroNavigator Time Domain Capture to view the Raw Scores and/or Z Scores of Phase Shift and Phase Lock by purchasing the swLORETA Phase Reset Normative Database (2 month - 82 years). Must first purchase NeuroNavigator and the swLORETA Current Source Density Normative Database (NNZ) add-ons to NeuroGuide.